Fluke T+ Digital Electrical Voltage and Continuity Meter is safer than traditional solenoid testers and fully compliant with NFPA 70E. The T+ Electrical Tester offers all the functionality that electricians look for in volt meters and voltage and continuity testers such as: three ways to detect ac/dc voltage: light, sound, and vibration, added functionality of a GFCI trip and continuity beeper, plus the convenience of a built-in flashlight, comes with a rotary field indicator for troubleshooting three-phase systems, resistance measurement to 9.99 KOhms, as well as a backlit LCD display for easier viewing. Solenoid tester features solid-state tester design, CAT IV 600 V, CAT III 1000 V rated, Complies with NFPA 70E when used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment.Fluke Tester/Fluke Meter includes: Test lead wrap, TP2 test probes, User manual.Additional Information:Manufacturer Specification Sheet (PDF File)
Features
- 3 forms of ac/dc voltage indication: light, sound, and vibration for added user protection and convenience
- Detect live voltage even when the batteries are dead
- Extra heavy-duty, replaceable test leads for more flexibility and durability
- CAT IV 600 V, CAT III 1000 V rated for added user protection
- Continuity beeper
- Bright LED flashlight for work in poorly lit areas
- GFCI Trip
- On/Off switchable beeper, selectable according to your environment
- Compliant with latest NFPA 70E recommendations*
- Replaceable test probes for added flexibility and convenience
- Convenient probe storage on the back
- Probe holder for easier testing
- Hazardous voltage warning light for added user protection
- Test lead strap included for better test lead management
- AC/DC Voltage: 12 V ? 600 V on LED bar
- Auto-off saves battery power
- 2-year warranty
Specifications
- Model Number: T+
- Item Number: 2548094
- Temperature: Operating: -10 °C to 55 °C (14 °F to 131 °F), Storage: -30 °C to 60 °C (-22 °F to 140 °F)
- Relative humidity: 0 °C to 30 °C (32 °F to 86 °F): 90 %, 30 °C to 40 °C (86 °F to 104 °F): 75 %, 40 °C to 50 °C (104 °F to 122 °F): 45 %
- Altitude: Operating: 2,000 m (approx. 6,561.6 ft), Storage: 0,000 m (approx. 32,808.4 ft)
- Battery type/life: AAA (2); 40 hours
- Shock, vibration: Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument
- Safety: ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV, Compliance to NFPA 70E
- AC Bandwidth: 45 Hz to 66 Hz
- Maximum working voltage: 1000 V ac/dc
- Maximum measurable voltage: 600 V ac/dc
- Duty cycle: Indefinitely for voltages up to 240 V, Voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off, Voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s
- Voltage hazard LED: LEDs turn on at voltages > 30 V ac/dc ± 35 %
- LED voltage indication levels: 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V
- LED voltage indication levels for Canadian version: 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 347 V, 480 V, 600 V
- LEDs: LEDs turn on between 90 % and 100 % of the indicated voltage on the LED, except for the 12 V LED which turns on between 50 % and 100 %
- GFCI Test current: 100 V - 150 V @ 6 mA - 9 mA ac, 150 V - 240 V < 12 mA
- Standard input test current: < 5 mA
- Size (HxWxL): 1.3 in x 2.15 in x 7.6 in (3.3 cm x 5.46 cm x 19.3 cm )