Digital Electrical Voltage and Continuity Tester

Fluke T+ Digital Electrical Voltage and Continuity Meter (Open Box Item)

by Fluke

Description

Fluke T+ Digital Electrical Voltage and Continuity Meter is safer than traditional solenoid testers and fully compliant with NFPA 70E. The T+ Electrical Tester offers all the functionality that electricians look for in volt meters and voltage and continuity testers such as: three ways to detect ac/dc voltage: light, sound, and vibration, added functionality of a GFCI trip and continuity beeper, plus the convenience of a built-in flashlight, comes with a rotary field indicator for troubleshooting three-phase systems, resistance measurement to 9.99 KOhms, as well as a backlit LCD display for easier viewing. Solenoid tester features solid-state tester design, CAT IV 600 V, CAT III 1000 V rated, Complies with NFPA 70E when used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment.Fluke Tester/Fluke Meter includes: Test lead wrap, TP2 test probes, User manual.Additional Information:Manufacturer Specification Sheet (PDF File)

Features

  • 3 forms of ac/dc voltage indication: light, sound, and vibration for added user protection and convenience
  • Detect live voltage even when the batteries are dead
  • Extra heavy-duty, replaceable test leads for more flexibility and durability
  • CAT IV 600 V, CAT III 1000 V rated for added user protection
  • Continuity beeper
  • Bright LED flashlight for work in poorly lit areas
  • GFCI Trip
  • On/Off switchable beeper, selectable according to your environment
  • Compliant with latest NFPA 70E recommendations*
  • Replaceable test probes for added flexibility and convenience
  • Convenient probe storage on the back
  • Probe holder for easier testing
  • Hazardous voltage warning light for added user protection
  • Test lead strap included for better test lead management
  • AC/DC Voltage: 12 V ? 600 V on LED bar
  • Auto-off saves battery power
  • 2-year warranty

Specifications

  • Model Number: T+
  • Item Number: 2548094
  • Temperature: Operating: -10 °C to 55 °C (14 °F to 131 °F), Storage: -30 °C to 60 °C (-22 °F to 140 °F)
  • Relative humidity: 0 °C to 30 °C (32 °F to 86 °F): 90 %, 30 °C to 40 °C (86 °F to 104 °F): 75 %, 40 °C to 50 °C (104 °F to 122 °F): 45 %
  • Altitude: Operating: 2,000 m (approx. 6,561.6 ft), Storage: 0,000 m (approx. 32,808.4 ft)
  • Battery type/life: AAA (2); 40 hours
  • Shock, vibration: Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument
  • Safety: ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV, Compliance to NFPA 70E
  • AC Bandwidth: 45 Hz to 66 Hz
  • Maximum working voltage: 1000 V ac/dc
  • Maximum measurable voltage: 600 V ac/dc
  • Duty cycle: Indefinitely for voltages up to 240 V, Voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off, Voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s
  • Voltage hazard LED: LEDs turn on at voltages > 30 V ac/dc ± 35 %
  • LED voltage indication levels: 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V
  • LED voltage indication levels for Canadian version: 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 347 V, 480 V, 600 V
  • LEDs: LEDs turn on between 90 % and 100 % of the indicated voltage on the LED, except for the 12 V LED which turns on between 50 % and 100 %
  • GFCI Test current: 100 V - 150 V @ 6 mA - 9 mA ac, 150 V - 240 V < 12 mA
  • Standard input test current: < 5 mA
  • Size (HxWxL): 1.3 in x 2.15 in x 7.6 in (3.3 cm x 5.46 cm x 19.3 cm )
  • Weight: 9.9 oz (0.28 kg)*When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment